Skip to content
KOEN

Thermal Clutch

A thermal control module that detaches the cooling body during heating to block heat loss, then engages precisely at bond completion to absorb heat through solid conduction.

서멀클러치 / Thermal Clutch / 热离合

Where the air jet reaches its ceiling

The gap is set by the working fluid itself. Raising the flow rate does not close it, because vibration and particles constrain bonding precision before the thermal gain arrives.

Air jetSolid conduction
Thermal conductivity0.026 to 0.037 W/m·K170 to 400 W/m·K
Interface coefficient h500 to 1,000 W/m²K20,000 to 50,000 W/m²K

The interface coefficient differs by about 40x. Estimated by Cools from the ranges above.

How one cycle works

  1. 01

    Detach

    During heating and pressing, the cooling body stays separated so no heat leaks out of the bond line.

  2. 02

    Engage

    At bond completion, the cooling body makes precise contact with the bond head.

  3. 03

    Absorb

    Heat crosses the solid interface into the cooling body.

  4. 04

    Discharge

    The absorbed heat leaves through a short discharge path.

  5. 05

    Detach again

    The body separates before the next cycle begins heating.

Why a clutch

Solid contact is good for cooling and bad for heating. A cooling plate that stays in contact cannot work. The clutch exists so the same interface can be there at one moment and gone the next.

Performance

Measured results and design targets are stated separately, each with its condition. They are not the same kind of number.

MetricValueStatusCondition
Cooling segment7.0 s to 3.4 s (51%)MeasuredFirst validation equipment, at equal bond quality
Cooling per bond4 s to 0.5 sDesign targetWhen interface contact reaches the required condition, typical TCB cycle
Bonder throughputUp to 3xDesign targetDepends on the share of cooling in the full cycle
Accumulated thermal exposureAbout 85% lowerDesign targetFor multi-layer stacking

Fitting an existing bonder

  • Two pipes, one valve channel

    The module mounts on an existing TCB bonder with two pipes and a single valve channel. It runs without electric power.

  • The recipe stays

    Bonding recipes and underfill are untouched. The same module covers HBM3E and HBM4.

Ask about a retrofit

Not to be confused with TIM

Thermal Clutch

A device. It connects and disconnects the heat path on demand.

Thermal interface material

A material. It stays in the interface at all times.